I-Ventilator yesibhedlela engahlanyisi i-ST-30K

Incazelo emfushane:

Amathuba angcono okusinda: Ukusinda kwe-NIV okuthuthukisiwe ezilungiselelweni zokunakekelwa okubucayi - nokuthi kunenzuzo kakhulu uma kusetshenziswe kusenesikhathi kunokuba kube yindlela yokwelapha yokuhlenga.


imininingwane yomkhiqizo imgs

Imininingwane Yomkhiqizo

ST-30K OH-30H

Izincazelo

I-Non-invasive ventilation (NIV) ukusetshenziswa kokusekelwa kokuphefumula okulawulwa ngemaski yobuso, imaski yamakhala, nomaumakalabha.Umoya, ngokuvamile one-oxygen eyengeziwe, unikezwa nge-mask ngaphansi kwengcindezi enhle;ngokuvamile inani lokucindezela liyashintshana kuye ngokuthi othile uyaphefumula noma aphume.

I-Non-invasive ventilation (NIV) iwukulethwa komoyampilo (ukwesekwa komoya) ngemaski yobuso futhi ngenxa yalokho iqeda isidingo somzila womoya we-endotracheal.I-NIV ifinyelela izinzuzo zokuqhathanisa zomzimba nomoya omncane ojwayelekile ngokunciphisa umsebenzi wokuphefumula nokwenza ngcono ukushintshaniswa kwegesi.

Izinhlelo zokusebenza

I-Acute Respiratory Distress Syndrome (ARDS) ibonakala ngokuhluleka kokuphefumula kokuqala, ukungaboni kahle kwamaphaphu kanye ne-hypoxemia enzima.Ukusetshenziswa kwe-NIV kungasiza ukugwema izinkinga ezifana nokukhuphuka kwenyumoniya ehambisana nama-ventilator.kanye ne-barotrauma.

Iziguli ezine-COVID-19 ezaziwayo noma okusolwa ukuthi ziyahluleka ukuphefumula kufanele zifakwe ngaphakathi futhi zifakwe umoya ekuqaleni kwesifundo sesifo ngaphandle kwenketho yokwelashwa okuhlaselayo kancane, okuhlanganisa nokungeniswa komoya okungahlaseli (NIV).

Izinzuzo

1.Ukugeleza okuphezulu:300L/min

2. Ukucindezela okukhulu kokuphefumula: 40cm H2O

3. Ukusebenza kwesinxephezelo sokuvuza, idivayisi inikeza isinxephezelo sokuvuza esiphezulu esingu-120 L/min, futhi ingafinyelela ukucindezela okuhlosiwe okusethiwe ukuze kwakhiwe isiteji sokucindezela ukuze kuqedelwe i-trigger enembile kanye nokushintsha.

Imininingwane

Ipharamitha

I-ST-30K

Imodi yokungenisa umoya

S/T, CPAP, S, T, PC, VAT, HFNC

Ukugxila komoyampilo

21%~100%, (nyuka ngo-1%)

Usayizi wesikrini

5.7 Intshi isikrini sombala

Isibonisi se-Waveform

Ingcindezi/ukugeleza

IPAP

4 ~ 40cm H2O

I-EPAP

4 ~ 25cm H2O

I-CPAP

4 ~ 20cm H2O

Ivolumu ye-tidal eqondisiwe

20 ~ 2500mL

Gcina i-BPM

1 ~ 60BPM

Isikhathi sokulondoloza

0.2~4.0S

Isikhathi sokuvuka

1 ~ 6 izinga

Isikhathi se-Ramp

0~60min

I-Ramp pressure

Imodi ye-CPAP: 4~20cm H2O Enye imodi: 4~25cm H2O

Ukunciphisa ingcindezi

1 ~ 3 izinga

I-Timin ezenzakalelayo

0.2~4.0S

I-Timax ezenzakalelayo

0.2~4.0S

Ukulungiselelwa kwe-I-Trigger

Okuzenzakalelayo, 1~3 ileveli

Ukulungiselelwa kwe-E-Trigger

Okuzenzakalelayo, 1~3 ileveli

Qalisa ukukhiya

Valiwe, 0.3~1.5S

Ukugeleza kwemodi ye-HFNC

10~70L/min

Ukugeleza okuphezulu

300L/min

Isinxephezelo sokuvuza esiphezulu

120L/min

Indlela yokulinganisa ingcindezi

Ishubhu lokuhlola ingcindezi lisohlangothini lwemaski

Ama-alamu

I-Apnea|Ukunqamuka|Ivolumu yomzuzu ophansi|Ivolumu yomsindo ophansi|Cisha amandla|Ukucindezela okuphezulu|Umoya-mpilo awutholakali|Ukunikezwa komfutho we-oxygen owedlulele|Ukunikezwa komfutho we-oxygen ophansi|Kuvalwa ishubhu lokucindezela|Ukungasebenzi kweturbine|Ukwehluleka kwenzwa yomoya-mpilo|Ukwehluleka kwenzwa yokugeleza komoya|Ukucindezela okuphansi |Ibhethri eliphansi|Ibhethri liphelile

I-apnea alarm range setting

0S, 10S, 20S, 30S

Ukulungiselelwa kwebanga le-alamu yokunqamula

0S, 15S, 60S

Idatha yokuqapha yesikhathi sangempela

Ukugxiliswa komoyampilo kwamanje|Ingcindezi yomthombo womoya-mpilo|Ingcindezi|Ukungenisa umoya ngomzuzu ngamunye|Izinga lokuphefumula|Ukuvuza kwamanje|Ivolumu yamanje|Indlela yokucupha

Ezinye izilungiselelo

Ukukhiya isikrini|Bonisa ukukhanya|Ukugeleza|Ingcindezi|I-Waveform|Isifinyezo somcimbi

Gcina ibhethri

8 amahora

 