umkhiqizo

I-Ventilator Engahlaseli Yomkhiqizo we-Micomme ST-30K

Incazelo emfushane:

Ukuncipha kwengozi yokutheleleka: Ukusetshenziswa kwe-NIV esikhundleni sokungenisa umoya ngomshini kuhlotshaniswa nengozi ephansi yokutheleleka nge-nosocomial.


imininingwane yomkhiqizo imgs

Imininingwane Yomkhiqizo

ST-30K ST-30K OH-30H

Incazelo

I-Non-invasive ventilation (NIV) ibhekisela ekuhlinzekeni kosizo lokuphefumula ngomoya ongenhla wesiguli usebenzisa imaski noma idivayisi efanayo.

Ukungena komoya okungahlaseli kusekela isiguli ngokuletha umfutho ofanele ophefumulayo nokuphelelwa umoya noma umthamo wamaza ukuze usekele isidingo sawo sokuphefumula, okuthuthukisa umoya wokungena komoya we-alveolar kanye nokuqasha i-alveoli ewile.

Isicelo

I-Acute Respiratory Distress Syndrome (ARDS) ibonakala ngokuhluleka kokuphefumula kokuqala, ukungaboni kahle kwamaphaphu kanye ne-hypoxemia enzima.Ukusetshenziswa kwe-NIV kungasiza ekugwemeni izinkinga ezinjalo ezifana nesigameko esiphezulu senyumoniya ehambisana nama-ventilator kanye ne-barotrauma.

Iziguli ezine-COVID-19 ezaziwayo noma okusolwa ukuthi ziyahluleka ukuphefumula kufanele zifakwe ngaphakathi futhi zifakwe umoya ekuqaleni kwesifundo sesifo ngaphandle kwenketho yokwelashwa okuhlaselayo kancane, okuhlanganisa nokungeniswa komoya okungahlaseli (NIV).

Inzuzo

6-leveli (100~600ms) isikhathi sokukhuphuka kwengcindezi, ukuze kuhlangatshezwane nezidingo zomzimba zamazinga okugeleza ahlukene ekuqaleni kogqozi.

Ukucindezela kukalwa ohlangothini lwemaski.I-hose yokulinganisa ingcindezi ixhunywe embobeni yokulinganisa ingcindezi eseduze ohlangothini lwesobunxele lomshini kanye ne-tee ekugcineni engezansi yemaski (ngaphakathi kwephakheji yemaski) ukuze kuqoqwe ukucindezela kumaski.

Ukucaciswa

Ipharamitha

I-ST-30K

Imodi yokungenisa umoya

S/T, CPAP, S, T, PC, VAT, HFNC

Ukugxila komoyampilo

21%~100%, (nyuka ngo-1%)

Usayizi wesikrini

5.7 Intshi isikrini sombala

Isibonisi se-Waveform

Ingcindezi/ukugeleza

IPAP

4 ~ 40cm H2O

I-EPAP

4 ~ 25cm H2O

I-CPAP

4 ~ 20cm H2O

Ivolumu ye-tidal eqondisiwe

20 ~ 2500mL

Gcina i-BPM

1 ~ 60BPM

Isikhathi sokulondoloza

0.2~4.0S

Isikhathi sokuvuka

1 ~ 6 izinga

Isikhathi se-Ramp

0~60min

I-Ramp pressure

Imodi ye-CPAP: 4~20cm H2O Enye imodi: 4~25cm H2O

Ukunciphisa ingcindezi

1 ~ 3 izinga

I-Timin ezenzakalelayo

0.2~4.0S

I-Timax ezenzakalelayo

0.2~4.0S

Ukulungiselelwa kwe-I-Trigger

Okuzenzakalelayo, 1~3 ileveli

Ukulungiselelwa kwe-E-Trigger

Okuzenzakalelayo, 1~3 ileveli

Qalisa ukukhiya

Valiwe, 0.3~1.5S

Ukugeleza kwemodi ye-HFNC

10~70L/min

Ukugeleza okuphezulu

300L/min

Isinxephezelo sokuvuza esiphezulu

120L/min

Indlela yokulinganisa ingcindezi

Ishubhu lokuhlola ingcindezi lisohlangothini lwemaski

Ama-alamu

I-Apnea|Ukunqamuka|Ivolumu yomzuzu ophansi|Ivolumu yomsindo ophansi|Cisha amandla|Ukucindezela okuphezulu|Umoya-mpilo awutholakali|Ukunikezwa komfutho we-oxygen owedlulele|Ukunikezwa komfutho we-oxygen ophansi|Kuvalwa ishubhu lokucindezela|Ukungasebenzi kweturbine|Ukwehluleka kwenzwa yomoya-mpilo|Ukwehluleka kwenzwa yokugeleza komoya|Ukucindezela okuphansi |Ibhethri eliphansi|Ibhethri liphelile

I-apnea alarm range setting

0S, 10S, 20S, 30S

Ukulungiselelwa kwebanga le-alamu yokunqamula

0S, 15S, 60S

Idatha yokuqapha yesikhathi sangempela

Ukugxiliswa komoyampilo kwamanje|Ingcindezi yomthombo womoya-mpilo|Ingcindezi|Ukungenisa umoya ngomzuzu ngamunye|Izinga lokuphefumula|Ukuvuza kwamanje|Ivolumu yamanje|Indlela yokucupha

Ezinye izilungiselelo

Ukukhiya isikrini|Bonisa ukukhanya|Ukugeleza|Ingcindezi|I-Waveform|Isifinyezo somcimbi

Gcina ibhethri

8 amahora